  • Bench Type Digital Multimeter VC8045
General Specification..!!
Content Description
Displaying LCD: Max display 19999(4 1/2)digit large LCD with back light and auto polarity display;
Measuring way: Double integral A/D converter;
Sampleing rate: approx. 3 times/sec;
Over range display: "1"
Working environment: (0-40)C, R.H<80% ;
Power supply: DC 220V/ 110V & 50/60Hz;
Dimension: 260mm*220mm*82mm=length*width*height
Weight: approx.2kgs;
Accessories: manual, test leads, power cord, box.


Technical Data
Accuracy =±(reading% + the lowest effective digit),
Temperature for accuracy guarantee:(23±5)℃,
R.H<80%,one year guaranteed from the production date.



Technical Specifications..
DCV
Range Accuracy Resolution
200mV ±(0.05%reading+3) 10uV
2V ±(0.05%reading+3) 100uV
20V ±(0.05%reading+3) 1mV
200V ±(0.05%reading+3) 10mV
1000V ±(0.1%reading+5) 100mV

Input impedance:10MΩ for all ranges;
Overload protection:200mV range: 250VDC or AC peak value.
Other range: 1000V DC or AC peak value.
ACV
Range Input Frequency Accuracy Resolution
200mV 50Hz–50kHz ±(0.8%reading+80) 10uV
2V 50Hz–20kHz ±(0.8%reading+80) 100uV
20V 50Hz–20kHz ±(0.8%reading+80) 1mV
200V 50Hz–5kHz ±(0.8%reading+80) 10mV
750V 50Hz–400Hz ±(1.0%reading+50) 100mV

The input value for accuracy guarantee should be larger than 10% of full range...
Input impedance: 2MΩ for all ranges...
Overload protection:200mV range: 250V DC or AC peak value, other range: 1000V DC or AC peak value...

DCA
Range Accuracy Resolution
20mA ±(0.35%reading+10) 1uA
200mA ±(0.35%reading+10) 10uA
2A ±(0.8%reading+10) 100uA
20A ±(0.8%reading+10) 1mA

Max. input voltage drop: 200mV..
Max. input current: 20A(within 10s)..
Overload protection: 2A/250V fuse,13A/250V fuse..
ACA
Range Input Frequency Accuracy Resolution
200mA 50Hz–5kHz ±(0.8%reading+80) 0.1μA
2A 50Hz–400Hz ±(1.0%reading+50) 1μA
20A 50Hz–400Hz ±(1.0%reading+50) 10μA

Max. input voltage drop: 200mV..
Max. input current: 20A(within 10s)..
Overload protection: 2A/250V fuse,13A/250V..
RESISTANCE
Range Accuracy Resolution
200Ω ±(0.1%reading+20) 0.01μA
2kΩ ±(0.1%reading+5) 0.1μA
20kΩ ±(0.1%reading+5) 1μA
200kΩ ±(0.1%reading+5) 10μA
2MΩ ±(0.1%reading+5) 100Ω
20MΩ ±(0.5%reading+5) 10kΩ

Open circuit voltage::less than 3V..
Over load protection: 250V DC or AC peak value;..
NOTE: At range 200 Ω, short-circuit the test leads to measure the wire resistance and then subtracts it from the real measurement..
CAPACITANCE
Range Accuracy Resolution
20nF; ±(3.5%+20) 1pF
2uF; ±(3.5%+20) 100pF
200uF; ±(5%+30) 10nF

Measuring frequency: approx. 400Hz..
Measuring voltage: approx. 40mV,...
Overload protection::36V DC or AC peak value..


FREQUENCY
Range Accuracy Resolution
20KHz; ±(1.0%reading+20) 1Hz
200KHz; ±(1.0%reading+20) 10Hz

Input sensitivity: 500mV rms..
Overload protection: 250V DC or AC peak value(within 15s)..
hFE
Range Displaying Test Condition
hFE NPN 0~1000 Base current is approx. 10μA,Vce is approx. 3V.


DIODE & CONTINUITY TEST
Range Description Test Condition
The measuring value is the approx. value for forward voltage drop. when the resistance under tested is less than 30Ω�10Ω, buzzer sounds and display the approx. value. The open circuit voltage is approx. 3V. Forward DCA is approx. 1mA, backward DCV is less than 3V.

ldbepurchase.com

Bench Type Digital Multimeter VC8045

Regular price $98.99
Regular price Sale price $98.99
Sale Sold out
Item
Availability
General Specification..!!
Content Description
Displaying LCD: Max display 19999(4 1/2)digit large LCD with back light and auto polarity display;
Measuring way: Double integral A/D converter;
Sampleing rate: approx. 3 times/sec;
Over range display: "1"
Working environment: (0-40)C, R.H<80% ;
Power supply: DC 220V/ 110V & 50/60Hz;
Dimension: 260mm*220mm*82mm=length*width*height
Weight: approx.2kgs;
Accessories: manual, test leads, power cord, box.


Technical Data
Accuracy =±(reading% + the lowest effective digit),
Temperature for accuracy guarantee:(23±5)℃,
R.H<80%,one year guaranteed from the production date.



Technical Specifications..
DCV
Range Accuracy Resolution
200mV ±(0.05%reading+3) 10uV
2V ±(0.05%reading+3) 100uV
20V ±(0.05%reading+3) 1mV
200V ±(0.05%reading+3) 10mV
1000V ±(0.1%reading+5) 100mV

Input impedance:10MΩ for all ranges;
Overload protection:200mV range: 250VDC or AC peak value.
Other range: 1000V DC or AC peak value.
ACV
Range Input Frequency Accuracy Resolution
200mV 50Hz–50kHz ±(0.8%reading+80) 10uV
2V 50Hz–20kHz ±(0.8%reading+80) 100uV
20V 50Hz–20kHz ±(0.8%reading+80) 1mV
200V 50Hz–5kHz ±(0.8%reading+80) 10mV
750V 50Hz–400Hz ±(1.0%reading+50) 100mV

The input value for accuracy guarantee should be larger than 10% of full range...
Input impedance: 2MΩ for all ranges...
Overload protection:200mV range: 250V DC or AC peak value, other range: 1000V DC or AC peak value...

DCA
Range Accuracy Resolution
20mA ±(0.35%reading+10) 1uA
200mA ±(0.35%reading+10) 10uA
2A ±(0.8%reading+10) 100uA
20A ±(0.8%reading+10) 1mA

Max. input voltage drop: 200mV..
Max. input current: 20A(within 10s)..
Overload protection: 2A/250V fuse,13A/250V fuse..
ACA
Range Input Frequency Accuracy Resolution
200mA 50Hz–5kHz ±(0.8%reading+80) 0.1μA
2A 50Hz–400Hz ±(1.0%reading+50) 1μA
20A 50Hz–400Hz ±(1.0%reading+50) 10μA

Max. input voltage drop: 200mV..
Max. input current: 20A(within 10s)..
Overload protection: 2A/250V fuse,13A/250V..
RESISTANCE
Range Accuracy Resolution
200Ω ±(0.1%reading+20) 0.01μA
2kΩ ±(0.1%reading+5) 0.1μA
20kΩ ±(0.1%reading+5) 1μA
200kΩ ±(0.1%reading+5) 10μA
2MΩ ±(0.1%reading+5) 100Ω
20MΩ ±(0.5%reading+5) 10kΩ

Open circuit voltage::less than 3V..
Over load protection: 250V DC or AC peak value;..
NOTE: At range 200 Ω, short-circuit the test leads to measure the wire resistance and then subtracts it from the real measurement..
CAPACITANCE
Range Accuracy Resolution
20nF; ±(3.5%+20) 1pF
2uF; ±(3.5%+20) 100pF
200uF; ±(5%+30) 10nF

Measuring frequency: approx. 400Hz..
Measuring voltage: approx. 40mV,...
Overload protection::36V DC or AC peak value..


FREQUENCY
Range Accuracy Resolution
20KHz; ±(1.0%reading+20) 1Hz
200KHz; ±(1.0%reading+20) 10Hz

Input sensitivity: 500mV rms..
Overload protection: 250V DC or AC peak value(within 15s)..
hFE
Range Displaying Test Condition
hFE NPN 0~1000 Base current is approx. 10μA,Vce is approx. 3V.


DIODE & CONTINUITY TEST
Range Description Test Condition
The measuring value is the approx. value for forward voltage drop. when the resistance under tested is less than 30Ω�10Ω, buzzer sounds and display the approx. value. The open circuit voltage is approx. 3V. Forward DCA is approx. 1mA, backward DCV is less than 3V.

Materials

Shipping & Returns

Dimensions

Care Instructions

  • Free Shipping

    Pair text with an image to focus on your chosen product, collection, or blog post. Add details on availability, style, or even provide a review.

  • Hassle-Free Exchanges

    Pair text with an image to focus on your chosen product, collection, or blog post. Add details on availability, style, or even provide a review.